[Classic Dossier] Element=etClassicDossier International Water Ski Federation 2001 Edition Homologation Dossier IMPORTANT NOTICE: It is not the intent of this form to add hours of extra work to the homologator's job, but rather to provide a quick checklist that gives visibility of the technical effort to the general skiing public. START OF HOMOLOGATION FORM code of competition:04AUS308 name of competition:Victorian Masters Date:10/01/2004 11/01/2004 Venue:Bridgewater On Loddon Organizing Country:AUSTRALIA Type of competition (National ) Were cash prizes or merchandise awarded (Yes/No) (No ) Homologator's and Chief Judge recommendation to Tournament Council (Fill in R-Record, L-Standing List, N-Not list capable) Event Round 1 Round 2 Round 3 Round 4 Slalom ( L) ( L) ( ) ( ) Tricks ( L) ( L) ( ) ( ) Jump ( L) ( L) ( ) ( ) OBLIGATORY COMPOSITION OF DOSSIER: 1 copy of this document including the homologation notice HOMOLOGATOR'S CHECKLIST If checked and all according to rules put OK in brackets. If checked and any variation to the rules put an X in the brackets and explain in "Remarks" section on last page. Not applicable is NA. 1. Boats and equipment (W 10.01) (OK) 2. Speed Control (W 10.07) (OK) Maunfacturer:Perfect Pass Software Version:6.04 slalom (OK) tricks (OK) jump (OK) 3. Arrangement for checking skis (W 10.03) (OK) 4. Measure lines and handles (W 10.04) ( ) slalom (OK) jump (OK) handles (OK) 5. Arrangement for checking of skier supplied handles (W 10.06) (OK) 6. Timing devices (W 11.03) (OK) 7. Homologation notice posted before start (OK) 8. Automatic timing-jump (OK) Optional Timing Method (NA) 9. Jump distance indication (W 13.11) (OK) 10.Video Jump Distance measurement (W 13.11)(OK) Backup - video tape or standard meters (Video ) 11.Automatic timing-slalom Dual Segment (NA) All Buoys (OK) 12.Position and height of slalom towers (OK) (W 14.05 and W diagram 6) 12a. 2 Towers x 2 Judges (OK) 2 Central Tower Judges (NA) Boat Video (NA) 13.Slalom buoys (W 14.06) (OK) 14.VHS video slalom endcourse (W 14.17) (OK) 15.Trick course checked (W diagram 3) (OK) 16.Position and height of trick towers (OK) (W 15.11) 16a. 5 Judges (NA) 1 x 3 Judges with video (OK) 2x 3 Judges with video (NA) 17.Semi-automatic timing-20sec (W 15.12) (OK) automatic median start (NA) 17a. Video Tricks Timing (OK) with Additional judge (OK) Chief Judge (NA) 18.VHS video tricks (W15.15) (OK) 19.7,000/10,000 points review judge (NA) (W 15.15) 17a.Video Tricks Timing system manufacturer (BackUp (Cunham Electronics) ) SLALOM COURSE TYPE :Cross Wire (See Remarks) JUMP COURSE JUMP MEASUREMENT SETUP VIDEO JUMP 40m Test buoy Survey x (-29.54) y (8.62 ) Video system x (-29.6 ) y (8.6 ) 60m Test buoy Survey x (-44.71) y (-10.13) Video system x (-44.7 ) y (-10.1 ) JUMP RAMP Width at top (W 13.02a) 4.24 m Width at bottom 4.24 m Top edge to 6.4m line left side (W 13.02b,h) 6.4 m Top edge to 6.4m line right side (W 13.02b.h) 6.4 m Top edge to 6.7m line left side (W 13.02b,h) 6.8 m Top edge to 6.7m line right side (W 13.02b.h) 6.8 m Length underwater from 6.7m line (W 13.02c) 0.65 m Maximum Deviation from plane Diagonal string measurement (W 13.02f) <2c cm Center string measurement (W 13.02f) <1c cm (OK/X) Apron under water (W 13.02g) (OK) Apron full length (W 13.02g) (OK) Sighting line (W 13.02i) (OK) Secure anchoring (W 13.02i) (OK) Apron Angle (W 13.02k) jump height 1.74 m (a) length of edge of apron from top corner to water 2.03 m (b) ratio of b/a (0.857) ( ) minimum 0.883 maximum 0.643 RAMP SETTING Right Side Left Side Setting Height Length Ratio Height Length Ratio 1.50 1.62 6.8 0.238 1.62 6.8 0.238 1.65 1.74 6.8 0.256 1.74 6.8 0.256 1.80 NA 6.75 NA 6.75 NON-VIDEO JUMP Note: The following section is only to be completed if the jumps were measured by protractors rather than video. Automatic meter system used (Yes/No) ( ) Protractor reading units (Degrees/Grades) ( ) METER SETUP Distance (T1 - T2/A - B) (XXX.XX meters) Distance (T2 - T3/B - C) (XXX.XX meters) if not a straight line Distance (T1 - T3/A - C) (XXX.XX meters) Inter-meter angles (if not a straight line) T1/A T2/B T3/C Meter T1/A XXXXX 180.0 180.0 Meter T2/B 0.0 XXXXX 180.0 Meter T3/C 0.0 0.0 XXXXX (note shown numbers are examples - fill in with actual numbers) SET UP SIGHTINGS Angle Ramp 15ET T1/A upper XXX.X XXX.X T1/A lower XXX.X XXX.X T2/B upper XXX.X XXX.X T2/B lower XXX.X XXX.X T3/C upper XXX.X XXX.X T3/C lower XXX.X XXX.X Using average of upper and lower readings (max difference 0.1 degrees) list the error triangles with an inscribed circle diameter (max 0.15) inscribed circle diameter at ramp X.XX meters inscribed circle diameter at 15ET X.XX meters Jump system survey results (X-Y coordinates) X Y Ramp XXX.XX XXX.XX Table 1/A XXX.XX XXX.XX Table 2/B XXX.XX XXX.XX Table 3/C XXX.XX XXX.XX Buoy 15ET XXX.XX XXX.XX Attach the computer printout file at the end after the Homologation Notice Computer program checked against (OK/X) "Computer Benchmark for Computed Distances" ( ) METER STATIONS Stability and horizontal level ( ) Protractors on same vertical line ( ) Protractor graduations (max 0.2 degrees) ( ) Radius of protractors (min 0.25 m) ( ) Accuracy of sighting arms ( ) END OF HOMOLOGATION FORM It is important to leave the above section in the exact format as it will be processed automatically. The following section is where free form comments are added and attachments are made. HOMOLOGATOR'S REMARKS End course Video was in use for all passes with competitors name recorded for all passes 13 metre or shorter. Check viewing is completed and all passes were well within video tolerance. End course Video transmitted to Judges Tower for review by CJ and additional Judge for immediate certification. Optical telelens was used to comply with rule 14.17 requirement and to achieve > 1/6th of the screen. Optical Magnification to X50 in use to achieve above requirement. Cross Wire Slalom course construction uses Central longitudinal s/s cable to ensure accuracy and stability. Water way has maximum width of 75 metres and 150,180,210 Jump guides on shoreline, not on survey certification. These markers achieved by tape measurement. Change to Jump course certification to open jump to 4 degrees allows buoys to be placed in water on shoreline. As this is a disadvantage to skier, recommend acceptance for listing or R/C. Trick Timing uses real time computer clock to provide start and 20 Second end timing. Video Trick timing was used as normal timing with above computer timing as backup. Video Trick timing also used as training for Judges panel. Jump measurement achieved across river ie. L-R jumping. Cameras on very high tower with video transmission to Computer centre. <30 degree spread of view. Note:- Jump height is set accurately to 1.62m to achieve a ratio of 0.238 which is 0.235 +/- 0.003. as per rule 13.02(b). Homologator: Tony Cunningham 19 Railway Terrace Kangaroo Flat 3555 Victoria AUSTRALIA Chief Judge: Craig Stephen This homologation record has been emailed to bcorson@home.com for EAME: email also to abottinelli@bluewin.ch ----------------------------------------------------------------------------- To be posted before the tournament starts HOMOLOGATION NOTICE Tournament Name:Victorian Masters Date:10/01/2004 11/01/2004 We recommend to the IWSF Tournament Council the following class of homologation: Event Round 1 Round 2 Round 3 Round 4 Slalom (L) (L) ( ) ( ) Tricks (L) (L) ( ) ( ) Jump (L) (L) ( ) ( ) Speed Control Manufacturer:Perfect Pass Software Version:6.04 Mode for tricks (if applicable):Classic Date Time Chief Judge Homologator Note: These recomendations may change during the competition. Remarks: End of Document