Homologation Dossier ----------------------------- cut here ---------------------------- International Water Ski Federation 2003 Edition Homologation Dossier IMPORTANT NOTICE: It is not the intent of this form to add hours of extra work to the homologator's job, but rather to provide a quick checklist that gives visibility of the technical effort to the general skiing public. START OF HOMOLOGATION FORM code of competition: 06AUS221 name of competition: NSW & ACT State Titles 2006 Date:25th & 26th March 2006 Venue: Molonglo River Canberra Organizing Country: Australia Type of competition ( Tournament Water Skiing ) Were cash prizes or merchandise awarded (Yes/No) ( No ) Homologator's and Chief Judge recommendation to Tournament Council (Fill in R-Record, L-Standing List, N-Not list capable) Event Round 1 Round 2 Round 3 Round 4 Slalom (N ) (N ) ( ) ( ) Tricks (L ) (L ) ( ) ( ) Jump (L ) (L ) ( ) ( ) OBLIGATORY COMPOSITION OF DOSSIER: 1 copy of this document including the homologation notice HOMOLOGATOR'S CHECKLIST If checked and all according to rules put OK in brackets. If checked and any variation to the rules put an X in the brackets and explain in "Remarks" section on last page. Not applicable is NA. 1. Boats and equipment (W 10.01) (ok) 2. Speed Control (W 10.07) (ok) Maunfacturer: Perfect Pass Software Version: Ver 6.5N slalom (ok) tricks (ok) jump (ok) 3. Arrangement for checking skis (W 10.03) (ok) 4. Measure lines and handles (W 10.04) (ok) slalom (ok) jump (ok) handles (ok) 5. Arrangement for checking of skier supplied handles (W 10.06) (ok) 6. Timing devices (W 11.03) (ok) 7. Homologation notice posted before start (ok) 8. Automatic timing-jump (XA) Optional Timing Method ( ) 9. Jump distance indication (W 13.11) (ok) 10.Video Jump Distance measurement (W 13.11)(ok) Backup - video tape or standard meters (video tape) 11.Automatic timing-slalom Dual Segment (NA) All Buoys (ok) 12.Position and height of slalom towers (ok) (W 14.05 and W diagram 6) 12a. 2 Towers x 2 Judges (ok) 2 Central Tower Judges ( ) Boat Video ( ) 13.Slalom buoys (W 14.06) (NA) 14.VHS video slalom endcourse (W 14.17) (NA) 15.Trick course checked (W diagram 3) (ok) 16.Position and height of trick towers (ok) (W 15.11) 16a. 5 Judges (ok) 1 x 3 Judges with video (NA) 2x 3 Judges with video (NA) 17.Semi-automatic timing-20sec (W 15.12) (NA) automatic median start (NA) 17a. Video Tricks Timing (ok) with Additional judge (ok) Chief Judge (ok) 18.VHS video tricks (W15.15) (ok) 19a.Video Tricks Timing system manufacturer ( Bob Corson Trick Timing Prog.) 20. 2nd Speed Control Display used all event(ok) SLALOM COURSE TYPE : Single wire course with aluminium arms and individual weights under each turn bouy. JUMP COURSE Single wire course with aluminium arms and individual weights and counterweights under each diamond. JUMP MEASUREMENT SETUP VIDEO JUMP 40m Test buoy Survey x ( 30.10) y ( -3.17) Video system x ( 30.00) y ( -3.08) 60m Test buoy Survey x ( 58.91) y ( 0.30) Video system x ( 58.78) y ( 0.52) JUMP RAMP Width at top (W 13.02a) 4.26 m Width at bottom 4.26 m Top edge to 6.4m line left side (W 13.02b,h) 6.40 m Top edge to 6.4m line right side (W 13.02b.h) 6.40 m Top edge to 6.7m line left side (W 13.02b,h) 6.70 m Top edge to 6.7m line right side (W 13.02b.h) 6.70 m Length underwater from 6.7m line (W 13.02c) 1.21 m Maximum Deviation from plane Diagonal string measurement (W 13.02f) 1.0 cm Center string measurement (W 13.02f) 0.5 cm (OK/X) Apron under water (W 13.02g) (ok) Apron full length (W 13.02g) (ok) Sighting line (W 13.02i) (ok) Secure anchoring (W 13.02i) (ok) Apron Angle (W 13.02k) jump height 1.61 m (a) length of edge of apron from top corner to water 1.95 m (b) ratio of b/a ( 0.825 ) minimum 0.883 maximum 0.643 RAMP SETTING Right Side Left Side Setting Height Length Ratio Height Length Ratio 1.50 1.605 6.80 0.236 1.610 6.80 0.237 1.65 1.730 6.75 0.256 1.730 6.80 0.256 1.80 1.800 6.70 0.268 1.800 6.80 0.268 NON-VIDEO JUMP Note: The following section is only to be completed if the jumps were measured by protractors rather than video. Automatic meter system used (Yes/No) ( ) Protractor reading units (Degrees/Grades) ( ) METER SETUP Distance (T1 - T2/A - B) (XXX.XX meters) Distance (T2 - T3/B - C) (XXX.XX meters) if not a straight line Distance (T1 - T3/A - C) (XXX.XX meters) Inter-meter angles (if not a straight line) T1/A T2/B T3/C Meter T1/A XXXXX 180.0 180.0 Meter T2/B 0.0 XXXXX 180.0 Meter T3/C 0.0 0.0 XXXXX (note shown numbers are examples - fill in with actual numbers) SET UP SIGHTINGS Angle Ramp 15ET T1/A upper XXX.X XXX.X T1/A lower XXX.X XXX.X T2/B upper XXX.X XXX.X T2/B lower XXX.X XXX.X T3/C upper XXX.X XXX.X T3/C lower XXX.X XXX.X Using average of upper and lower readings (max difference 0.1 degrees) list the error triangles with an inscribed circle diameter (max 0.15) inscribed circle diameter at ramp X.XX meters inscribed circle diameter at 15ET X.XX meters Jump system survey results (X-Y coordinates) X Y Ramp XXX.XX XXX.XX Table 1/A XXX.XX XXX.XX Table 2/B XXX.XX XXX.XX Table 3/C XXX.XX XXX.XX Buoy 15ET XXX.XX XXX.XX Attach the computer printout file at the end after the Homologation Notice Computer program checked against (OK/X) "Computer Benchmark for Computed Distances" ( ) METER STATIONS Stability and horizontal level ( ) Protractors on same vertical line ( ) Protractor graduations (max 0.2 degrees) ( ) Radius of protractors (min 0.25 m) ( ) Accuracy of sighting arms ( ) END OF HOMOLOGATION FORM It is important to leave the above section in the exact format as it will be processed automatically. The following section is where free form comments are added and attachments are made. HOMOLOGATOR'S REMARKS Give details of any variations of IWSF rules. List any alterations to the course, etc. duringthe competition. List any malfunction of equipment. Give any further information which might affect the Tournament Council's assement of the homologation. Almost at the end of the first day of skiing during the jump event the innermost line of the grid buoys was snagged and pulled out of line,so a new survey was done for this line only. Hence the reason for two surveys. This had no effect the first round of jump measurements,as the buoys had already been plotted. XA- Jump Timing was done with Perfect Pass Ver 6.5N Slalom was not rated as Listing as there was no survey done on the course due to the homologator not being able to carry one out due to a Specialists appointment. The video cameras for the trick timing were situated on the top of the main judging tower and had a totally unrestricted view of the competitors at all times. The 150,180 & 210 metre buoys are slightly out of line, respectively 0.7m, 0.9m, & 1.0m. As this,can only be considered a hinderance I see no reason not to make the jump event a Listing event. Homologator: Bob Beazley (name and address) 2 Broad Street Narrandera 2700 New South Wales Email: bobeazley@bigpond.com Chief Judge: Pam Beazley (name and address) 2 Broad Street Narrandera 2700 New South Wales This homologation record has been emailed to bcorson@comcast.net for EAME: email also to abottinelli@bluewin.ch ----------------------------------------------------------------------------- To be posted before the tournament starts HOMOLOGATION NOTICE Tournament Name: NSW & Act State Titles Date: 25th & 26th March 2006 We recommend to the IWSF Tournament Council the following class of homologation: Event Round 1 Round 2 Round 3 Round 4 Slalom (N) (N) ( ) ( ) Tricks (L) (L) ( ) ( ) Jump (L) (L) ( ) ( ) Speed Control Manufacturer: Perfedt Pass Software Version: Ver 6.5N Mode for tricks (if applicable):_____Tricks____________ Date _25-3-06_ __26-3-06 _______ Time __8am____ __8am___ _______ Chief Judge Homologator __Pam Beazley_______ _Bob Beazley____ Note: These recomendations may change during the competition. Remarks: The 150,180 & 210 metre buoys are slightly out of line, respectively 0.7m, 0.9m, & 1.0m. As this,can only be considered a hinderance I see no reason not to make the jump event a Listing event. End of Document